Keeping your SmartLase in A1 condition
You can almost set and forget your SmartLase laser coding
system: there are no consumables, no warm up or shut down routines, and
just three easy steps will keep it in perfect condition.
1) Clean the laser nozzle with acetone
on a soft bud once a week. This will preserve the nozzle and ensure codes
are easy to read.
2) Record the SmartLase's parameters, including laser intensity,
font type, dwell time, image height and width so they can be reinstated
if lost. Markem makes restoration of settings foolproof with its optional
Expert Utility software - simply upload or download messages and parameters
directly from your notebook or PC.
For maximum resolution, the focal distance of the laser should be 43.1mm
from the front of the nozzle to the product. Make your own gauge to keep
with the unit and check the distance regularly.
3) Once a year, treat your SmartLase to a comprehensive inspection
by a trained Unimark technician.
SmartLase is the ultimate quiet achiever - a quick weekly clean and an
annual check-up is all that's needed to keep it working at its best.
|